Functions for cw, D connections for cw d cw operation, Q4 cw paddle – Icom I706MKTMG User Manual

Page 36: Q3 bk-in delay m4 brk 1/4 agc

Advertising
background image

33

4

RECEIVE AND TRANSMIT

D Connections for CW

D CW operation

Connect a paddle or straight key as above.

Select CW (or CWå) mode with [MODE].

Set CW break-in operation as semi break-in, full
break-in or OFF.

• Push [DISPLAY] one or two times to select M, if necessary.
• Push [MENU] one or more times to select M4.
• Push [

(F-2)

BRK] one or more times to select the desired

condition:

➧ “F-BK”:

full break-in

➧ “BK”:

semi break-in

➧ No indicator: no break-in (ACC socket connection is

necessary as above.)

Set the CW delay time when semi break-in opera-
tion is selected.

➥ Push [DISPLAY] for 2 sec. to select quick set

mode; push [MENU] one or more times to select
Q3 BK-IN DELAY; then rotate the main dial
to set the desired delay time (see p. 48 for
details).

CW

Q4

CW PADDLE

CW

CW

CW

CW

Paddle

[ELEC KEY]

[MICROPHONE]

See p. 34 for
connection details:
Paddle operation from
front panel MIC connector.

Straight key

Microphone

Quick set mode setting

Rear panel

4

8

12

144/430 MHz

HF/50 MHz

[ACC]

1

2

3

7

6

5

9 10 11

13

For no break-in operation:

Connect an external switch such

as a foot switch; or use the

RTTY SEND terminal for all

bands. (See p. 35.)

Functions for CW

BK

VFO A

CW

CW

Q3 BK-IN DELAY

M4

BRK

1/4

AGC

CW mode and semi
break-in operation is
selected.

Delay time of 6.0 dots is
selected in quick set
mode for semi break-in
operation.

CH

P

O

S1

5

5

3

7

9

20

40

10

60dB

Advertising