G2 10k str, D measuring swr, M3 fil nb met – Icom I706MKTMG User Manual

Page 41: G2 50k str, G2 50k str str, Confirm that the output power is over 30 w, Push [menu] one or more times to select m3, Push, Met] to select the swr meter

Advertising
background image

38

4

RECEIVE AND TRANSMIT

The IC-706MKIIG can measure SWR in 2 ways:
(A) Spot measurement; or (B) Plot measurement.

(A) Spot measurement

Confirm that the output power is over 30 W.

Push [MENU] one or more times to select M3.

Push [

(F3)

MET] to select the SWR meter.

Push [MODE] one or more times to select CW or
RTTY operation.

• Key down or push [PTT] to transmit; then read the actu-

al SWR from the meter:
➠ ≤ 1.5 well matched antenna

➠ > 1.5 check antenna or cable connection, etc.

(B) Plot measurement
Plot measurement allows you to measure the SWR
over an entire band.

q Confirm that the output power is over 30 W.
w Push [DISPLAY] twice to select G1.
e Push [MENU] to select G2.
r Set the center frequency for the SWR to be mea-

sured.

t Push and hold [

(F1)

10k] one or more times to

select the desired frequency pitch.

y Push and hold [

(F2)

] one or more times to select

the desired step.

u After selecting the desired pitch and step, push

[

(F3)

STR] to measure the SWR.

i Push and hold [PTT] to display the SWR in a bar

graph readout.

o When [PTT] is released, the frequency marker and

frequency indication move to the next frequency to
be measured.

!0 Repeat steps i.and o to measure SWR over the

entire frequency range.

!1 When the measured SWR is less than 1.5, the

antenna is well matched.

SWR

The IC-706MKIIG has a built-in circuit for measuring
antenna SWR while in SSB mode—no external equip-
ment or special adjustments are necessary.

NOTE: The SWR of ANT1 only can be read since

ANT2 has no measuring circuit.

D Measuring SWR

CH

VFO A

SWR

S1

1 1.5 2

3

5

3

7

9

20

40 60dB

CW

BLANK

SWR

1 1.5 2

3 5

10

The best match is in this range.

M3 FIL NB

MET

G2 10k

STR

Frequency span

Step bar indication
Frequency indication mark

Measure start indicator

Span

Push [F-1] for 1 sec. to change the
selected span.

Step bar

Push [F-2] for 1 sec. to change the step
bar (3, 5, 7 or 9 steps are available.

Marker

Indicates the currently active step bar.

Start

Flashes while the SWR is being mea-
sured.

Step o

The antenna is well matched in this range

CH

VFO A

P

O

S1

5

5

3

7

9

20

40

10

60dB

USB

BLANK

G2 50k

STR

4.0
3.5
3.0
2.5
2.0

1.5
1.0

CH

VFO A

P

O

S1

5

5

3

7

9

20

40

10

60dB

BLANK

G2 50k

STR

STR

___

RTTY