70˚ mfx, 90˚, 70˚ lift and 90˚ lift footrests, Model phw93 and ph904a front riggings, 70° mfx, 90°, 70° lift and 90° lift footrests – Invacare Compass SPT PH904A User Manual

Page 32: Mounting tube (figure 4.3)

Advertising
background image

SECTION 4—FRONT RIGGINGS

Compass™SPT™

32

Part No 1122134

4. Securely tighten the hex screw and

coved spacer.

5. Install the footrest assembly onto the

wheelchair. Refer to
Installing/Removing Swingaway Front
Riggings on page 30.

6. Repeat STEPS 1-5 for the opposite side

of the wheelchair, if necessary.

FIGURE 4.3 Adjusting Footrest Height -

60°, 70° and 70° Taper

70° MFX, 90°, 70° LIFT and 90° LIFT Footrests

NOTE: For this procedure, refer to FIGURE 4.4.

1. Remove any accessories that are attached to the footrests.

2. Remove the socket bolt, coved washer and locknut that secure the footplate to the

footrest support.

3. Reposition the footplate to the desired

height.

4. Reinstall the socket bolt through the

mounting holes of the footplate and
footrest support.

ƽ WARNING

DO NOT overtighten socket bolt and

locknut. Footrest MUST be able to

rotate upward from the horizontal to

the vertical position.

5. Secure the footplate to the footrest

support with the coved washer and
locknut.

FIGURE 4.4 Adjusting Footrest Height -

70° MFX, 90°, 70° LIFT and 90° LIFT

Footrests

Model PHW93 and PH904A Front Riggings

NOTE: For this procedure, refer to FIGURE 4.5 on page 33.

1. Remove any accessory from the footrest(s).

2. Remove the footrest from the wheelchair. Refer to Installing/Removing Swingaway

Front Riggings on page 30.

NOTE: Lay footrest on a flat surface to simplify procedure.

Footrest

Mounting

Tube

Coved
Spacer

Hex Screw

Footrest Upper

Support

Height

Adjustment

Holes

Socket Bolt

Locknut

Footrest Support

Footplate