2 connecting the power cord, Connect the camera to dc 12 v or ac 24 v, Warning – JVC V.NETWORKS VN-C10 User Manual

Page 14: Power cord

Advertising
background image

14

Connect the camera to DC 12 V or AC 24 V.

1-2 Connecting the Power Cord

Preparations (Step 1 Connection and Installation)

CLASS 2 ONL

Y F

or USA

ISOLA

TED PO

WER ONL

Y

POWER

G

2

2

1

1

OUT COM

ALARM

DC12V

A

C24V

OUTPUT

INPUT

PUSH

Power
indicator
lamp

For EUR

OPE

To
Power

10BASE-T/100BASE-TX

For USA

DO NOT CONNECT TO THE
TELEPHONE NETWORK

For a system with multiple VN-C10s
In a system where more than one VN-C10 are used, turn on the power for a VN-C10 first and
proceed the setting to 2-4 Other Settings with V.Networks Setup Tool. Only then turn on the power for
a second one and go on to 2-4. Repeat the procedure for the other cameras.

WARNING

Connect with the appropriate power-supply voltage.The rated voltage for VN-C10 is DC 12 V
or AC 24 V, 50 Hz/60 Hz. If a voltage exceeding the rating is supplied, malfunction, or in the
worst case, fuming or fire, may be caused.
For AC 24 V, ensure that the primary side is insulated with the secondary one.

Note

The IP address of VN-C10 is set to “198.168.0.2” at the factory. Proper access cannot be
established due to IP address redundancy if the power is turned on for multiple cameras at
one time under a single LAN environment. Do not turn on the power for multiple cameras
at the same time.
If an IP address redundancy occurred, ensure that only one VN-C10 exists
on a single LAN environment and wait for some time (at least 10 minutes). Or turn off the
power once for all network equipment and turn it on again for proper access to VN-C10.

The power indicator is lit when the power is turned
on.

Power Cord

• Do not connect the power cord to DC 12 V and

AC 24 V at the same time.

• Use a lug plate to securely connect the power

cord to the power ter minals and avoid
misconnection or loose connection.

• For DC 12 V connection, ensure that the

polarities, positive and negative, are correctly
oriented.

• For DC 12 V connection, the ripple voltage

should not exceed 50 mV.

Length: 30 m maximum
UL1007, UL1015 or equivalent
AWG #20 or equivalent, or higher

VN-C10_E_01-43.pm65e

14/04/03, 10:13 AM

14

Advertising