Alarm settings, 4 alarm settings – JVC V.NETWORKS VN-C10 User Manual

Page 70

Advertising
background image

70

Operations (Step 6 Operations with a Web Browser)

6-4 Settings with a Web Browser (4. Alarm Settings)

Alarm Setting Window:
http://******/alarm-e.html (****** represents the URL of VN-C10.)
This section describes the setting of actions of VN-C10 when an alarm signal has been received.

Item

Effect

Alarm In

Specifies the action when an alarm signal has been received.

Alarm 1 and 2

Specifies the action when an alarm signal has been input to
[Alarm 1] and/or [Alarm 2].

On/Off

Select [On] if the alarm terminals [Alarm 1] and/or [Alarm 2]
are to be used. If not to be used, select [Off].

Alarm Out

If [On] is selected here, alarm signals are output to the
[ALARM OUTPUT] terminal located on the rear panel.

Relay Alarm

Sets the relay alarm function, which is activated when two
alarms are successively received within a certain period of
time.

On/Off

Select whether to enable or disable the relay alarm function.

Relay Alarm Setting

Sets the sequence and interval of alarm input.

Alarm Out

If [On] is selected here, alarm signals are output to the
[ALARM OUTPUT] terminal located on the rear panel.

Alarm Out

On/Off

Select [On] for alarm signals to be output to the [ALARM
OUTPUT] terminal located on the rear panel.

Momentum

Sets the duration for sending alarm output signals.

Value

Sets whether to output high or low signals for alarm output.

Power on Init

If [Yes] is selected, the alarm signal, which was set upon
power connection, is output once.

Caution

Perform the output setting appropriately according to the equipment to which signals are

sent.

When the alarm setting is complete, check whether the alarm functions are working prop-

erly.

Click [Apply] to update the settings.