2-4 Other Settings with V.Networks Setup Tool [2. Alarm Setting] (continued)

1

Alarm 1
Select [ON] to convert signals input to the
[ALARM INPUT 1] terminal to [Alarm 1] sig-
nals.

If [Alarm Output] is selected, alarm signals are
sent to the [ALARM OUTPUT] terminal ac-
cording to the output port setting.

2

Alarm 2
Select [ON] to convert signals input to the
[ALARM INPUT 2] terminal to [Alarm 2] sig-
nals.
If [Alarm Output] is selected, alarm signals are
sent to the [ALARM OUTPUT] terminal ac-
cording to the output port setting.

3

Motion Detection
Select [ON] for motion within the set area to
be recognized as a cause for an alarm.
If [Alarm Output] is selected, alarm signals are
sent to the [ALARM OUTPUT] terminal ac-
cording to the output port setting.

4

Relay Alarm
Select here to enable the alarm function, which
is activated when two alarms are successively
received within a certain period of time.
The sequence and interval of alarm input can
be set.
If [Alarm Output] is selected, alarm signals are
sent to the [ALARM OUTPUT] terminal ac-
cording to the output port setting.

Note

• A second alarm input enables this relay

alarm function, and alarm will not be acti-
vated for this second input.

• Unless the alarm output is enabled, this

function is not activated even if [Alarm
Output] of the [Alarm Settings] screen is
selected.

5

Retry [1 to 3]
This function sets how many times an alarm
alert to [V.Networks Controller] is repeated (1
to 3).

Note

Depending on the LAN environment, alarm
alert might fail. If it fails, set the value to “3”.
In such a case, alarm by [V.Networks Con-
troller] itself is set off only once.

6

Alarm force output

If [Output] is pressed, alarm signals are sent
to the [ALARM OUTPUT] terminal. This forced
output is used for checking the alarm func-
tion.

7

Out port setting
Enable this function to output alarm signals
to the [ALARM OUTPUT] terminal.
Using output values, set the polarity, high or
low, and output time (1 to 5000 ms) accord-
ing to the equipment connected.
If initialization is set to start, the set alarm sig-
nal is output once when the power is turned
on.

8

List
Press here to show the IP addresses of the
PCs to which alarm input is reported. To de-
lete an IP address, select the address and
press [Delete].

Note

• If more than 10 destinations are set, this

function is not activated.