17

This terminal is for connecting with an alarm annunciator such as an indicator, a
lamp or a buzzer.

1-4 Connecting the Alarm I/O Terminals (continued)

Alarm Output Terminal

Output Requirements

• Equivalent to NPN open collector output

(The output logic is set with [V.Networks Setup
Tool.])

• Allowed applied voltage: DC 12 V max.
• Allowed input current: 300 mA
• Momentary output: 2 to 5000 ms

(The duration is set with [V.Networks Setup
Tool.])

VN-C10

Annunciator

Connection

Example 1

Output
terminal

IN

R

DC 12 V

(Alarm output equivalent circuit)

COM
terminal

COM

Grounding
terminal

GND

MAX
300 mA

MAX
12 V

Annunciator

Connection

Example 2

IN

R

DC
12 V

COM

GND

Buzzer, lamp, LED etc.

Annunciator

Connection

Example 3

R

DC
12 V

Buzzer, lamp, LED etc.

Caution

Connect the VN-C10 grounding terminal to
the one of the annunciator.