Accessing original greenstar display fault codes – John Deere OMPC20964 User Manual

Page 139

Advertising
background image

Troubleshooting and Diagnostics

OUO6050,0002234

–19–14NOV06–4/4

Select Diagnostic Address icon (soft-key G) button (A)
for 4 seconds and release.

This action will take the display out of technician mode.

OUO6050,0002235

–19–14NOV06–1/1

Accessing Original GREENSTAR Display Fault Codes

GREENSTAR

Display IV Fault Codes

Select Menu -> Original GreenStar Display icon
(soft-key H). The 2100/2600 display now is emulating
the GreenStar IV display. Then follow directions for
each components’ fault codes.

Press the INFO button on the GREENSTAR Display.
Then press the button next to the entry GreenStar
Display
followed by pressing the button next to the
words Recent Problems. The codes will be displayed
on this page with a short description following the
code. To clear these Fault Codes, press the button
next to the words Clear.

Messages generated by a problem controllers are sent
to the GREENSTAR Display over the CAN Bus
network.

STARFIRE iTC Diagnostic Trouble Codes

STARFIRE iTC Diagnostic Trouble Codes can be
viewed by pressing the INFO button on the
GREENSTAR Display. Then pressing the button next
to the entry StarFire Receiver. Then press the Page
button once to get to Page 2. Then press the button
next to Diagnostic Trouble Codes. This page will
show the Active and Previously Active codes.

Pressing the button next to a code will supply the
operator or technician more information about the
code. It will give a detailed description, time of last
occurrence, and occurrence count. To clear the codes
go back to previous page and press button next to
Clear All Codes.

Terrain Compensation Module Fault Codes

Terrain Compensation Module Fault Codes can be
viewed by pressing the INFO button on the
GREENSTAR Display. Then pressing the button next
to the entry TCM followed by pressing the button next
to the words Fault Codes . The codes will be
displayed on this page with a short description
following the code. To clear these Fault Codes, press
the button next to the words Clear.

Parallel Tracking Fault Codes

Parallel Tracking Fault Codes can be viewed by
pressing the INFO button on the GREENSTAR
Display. Then pressing the button next to the entry
Tracking followed by pressing the button next to the
words Fault Codes . The codes will be displayed on
this page with a short description following the code.
To clear these Fault Codes, press the button next to
the words Clear.

GREENSTAR is a trademark of Deere & Company

40-3

121907

PN=139

Advertising