<fun> Description
0
Minimum functionality. Modem is OFF
1
Full functionality. Modem is ON
3.18 AT+CIND Indicator Control
Description Command Possible
Responses
Set Indicator Control AT+CIND=[<ind>
[,<ind>[,…]]]
•_ +CME ERROR: <err>
•_ OK
•_ ERROR
Read the current
setting
AT+CIND?
•_ +CIND: <ind>,<ind>,…
•_ +CME ERROR: <err>
•_ OK
•_ ERROR
Test if the command
is supported
AT+CIND=?
•_ +CIND: (<descr>,(list of
supported <ind>s)),
(<descr>,(list of supported
<ind>s)),…
•_ +CME ERROR: <err>
•_ OK
•_ ERROR
Used to set the values of ME indicators. <ind> value 0 means that the
indicator is off (or in state which can be identified as “off” state), 1 means
that indicator is on (or in a state which is more substantial than “off” state), 2
is more substantial than 1, and so on. If the indicator is a simple on/off style
element, it has values 0 and 1. The number of elements is ME specific. If the
ME does not allow setting of indicators or it is not currently reachable, +CME
ERROR: <err> is returned. If a certain indicator is not writable, it cannot be
set. If the parameter is an empty field, the indicator will keep the previous
value.
Test command returns pairs, where string value <descr> is a maximum 16
character description of the indicator and compound value is the allowed
values for the indicator. If ME is not currently reachable, +CME ERROR:
<err> is returned (refer to GSM 07.07).
<ind> Description