Alarm recording tab — setting the image, Memory function when detecting the alarm 53 – Sony IPELA SNC-RZ25P User Manual

Page 53

Advertising
background image

A

d

mini

s

tra

ting
t

he

Came

ra

Recording Images in Memory — Image memory setting Menu

53

POP server name

This is necessary when POP before SMTP is selected
in Authentication.
Type POP (receiving mail) server name up to 64
characters. Otherwise type the IP address of POP server.
This setting is necessary when SMTP server that sends a
mail authenticates using the account of POP user.

User name, password

Type the user name and the password of the user who
has the mail account. This setting is necessary when
SMTP server that sends a mail authenticates.

Administrator e-mail address

Type the E-mail address of the recipient of the warning
mail (E-mail address of the camera Administrator), up to
64 characters.

OK/Cancel

See “Buttons common to every setting menu” on page
29.

Alarm recording Tab — Setting the
Image Memory Function when
Detecting the Alarm

You can set to record the image and audio file to the
memory linked with the external sensor input or with the
built-in motion detection function.

Alarm recording

Select On to set to record the image and audio file to the
memory linked with the external sensor input or with the
built-in motion detection function.

Image file name

Type the file name you want to assign to the images
when saving in the built-in memory. You can use up to
10 alphanumeric characters, - (hyphen) and _
(underscore) for naming.

Suffix

Select a suffix to add to the file name.
Date & time: The Date & time suffix is added to the

Image file name.
The Date & time suffix consists of lower two-digits
of year (2 digits), month (2 digits), date (2 digits),
hour (2 digits), minute (2 digits), second (2 digits)
and consecutive number (2 digits), thus 14-digit
number is added to the file name.

Sequence number: A consecutive number of 10 digits

between 0000000001 and 4294967295 and an
consecutive 2 digits number is added to the Image
file name.

Tip

A consecutive number added to Date & time and
Sequence number is used to identify each of multiple
files created with one alarm event.

Sequence number clear

Click Clear to reset the Sequence number suffix to 1.

Alarm

Select the connected alarm.
Sensor input1: The external sensor which is connected

to sensor input1 of the camera I/O port.

Sensor input2: The external sensor which is connected

to sensor input2 of the camera I/O port.

Motion detection: Click Motion detection button, and

the Motion detection setting page is displayed. You
can set the motion detection function (page 53).

Notes

Motion detection works only when the Video mode is

set to MPEG4 and the Cropping is set to Off.

• In the case that the synchronized preset position is

specified, the alarm event that happens during moving
to the preset position will be invalid.

Effective period

Set the period when the alarm detection is effective.
Always: The alarm detection is always effective.
Schedule: You can specify the period when the alarm

detection is effective in the schedule setting in the
other section.
Click Schedule and the setting menu for the effective
period is displayed. (“Setting the Schedule —
Schedule setting Menu” on page 59)

Advertising