SMC Networks SMC91C95 User Manual

Page 119

Advertising
background image

119

FIGURE 27 - ISA CONSECUTIVE READ CYCLES

BALE Tied High

VALID ADDRESS

VALID ADDRESS

VALID DATA

OUT

VALID DATA

OUT

t15

t4

t3

t20

t5

t6

Z

Z

A0-15
AEN, nSBHE

nIOCS16

nIORD

D0-15

t3

t4

t5

t6

t15

t20

Address, nSBHE, AEN Setup to Control Active

Address, nSBHE, AEN Hold after Control

Inactive

nIORD Low to Valid Data

nIORD High to Data Floating

A4-A15, AEN Low, BALE High to nIOCS16

Low

Cycle time*

Parameter

min

typ

max

units

25

20

185

40

30

25

ns

ns

ns

ns

ns

ns

IOCHRDY not used - t20 has to be met

*Note: The cycle time is defined only for consecutive accesses to the Data Register. These values assume
that IOCHRDY is not used.

Advertising