SMC Networks SMC91C95 User Manual

Page 120

Advertising
background image

120

FIGURE 28 - ISA CONSECUTIVE WRITE CYCLES

VALID ADDRESS

VALID ADDRESS

t15

t4

t3

t20

A0-15
AEN, nSBHE

nIOCS16

nIOWR

D0-15

VALID DATA IN

VALID DATA

t7

t8

BALE Tied High

t3

t4

t7

t8

t15

t20

25

ns

ns

ns

ns

ns

ns

Address, nSBHE, AEN Setup to Control Active

Address, nSBHE, AEN Hold after Control

Inactive

Data Setup to nIOWR Rising

Data Hold after nIOWR Rising

A4-A15, AEN Low, BALE High to nIOCS16

Low

Cycle time*

Parameter

min

typ

max

units

25

20

30

9

185

IOCHRDY not used - t20 has to be met

*Note: The cycle time is defined only for consecutive accesses to the Data Register. These values assume
that IOCHRDY is not used.