Sony BBV RX100 User Manual

Page 13

Advertising
background image

Rx100 installation manual V1.17 29 Aug 08.doc

Page 13

BBV Rx100/24 Supply Additional information

(iss. 6 pcb)


The RX100/24 can be powered from either 230Vac or 24Vac. The diagrams below shows the connections that
should be made for each supply voltage. Please note that when powered from 24Vac the 230Vac terminals will be
at mains voltages. To prevent the risk of shocks the fuse must be removed from the fuse holder and no connections
made to L and N. The 24Vac supply must be fused with a 315mA to protect the supply wiring.

Fig 9. RX100/24 iss. 6 pcb Connection details when operating from a 230Vac supply.




Important! When
operating the unit
from 24Vac, the fuse
from the 230Vac
connector fuse holder
must be removed. No
connections must be
made to this connector,
as it will have 230Vac
across the L & N
terminals.








Fig 10. RX100/24 iss. 6 pcb Connection details when operating from a 24Vac supply.

IMPORTANT! Remove fuse from fuseholder

and make no connection as these terminals

will have 230Vac across L and N.

24Vac

Supply

!

315mA Fuse

24Vac 100VA

output to power dome

230Vac Supply

Advertising