Rx100 installation manual V1.17 29 Aug 08.doc

Page 17

BBV Rx 100

Interface Receiver

Addendum to manual for the following dome:


Dynacolor 7720

COAXIAL TELEMETRY ONLY NOT 20mA

Rx100 software RX1_D4V7

Application Notes

Variable speed Pan/Tilt (single function at a time, pan or tilt or zoom or focus)
Zoom/Focus
16 full scene presets
2 preset patrols
4 alarm inputs driving to preset 1 – 4

Additional

Features

Tx400

Tx1000

Tx1500

DM

Sprite DM/DS/DSL/DS2

Dome Menu and ENTER

(twice)

‘#’ 1

'#' WASH

1 '#'

*889 002

*889 10 10 2

Exit Dome Menu

‘#’ 2

‘#’ WIPE

2 ‘#’

*889 003

*889 10 10 3

Dome Reset

(3

times)

‘#’ 4

‘#’ LIGHTS

4 ‘#’

*889 005

*889 10 10 5


Menu access – example using the Tx1500 system
Press 1# 1# will display the dome’s menu and put the Rx100 in menu mode. In this mode the joystick allows navigation and either IRIS
OPEN or IRIS CLOSE or 1# is used when ENTER is required. After exiting the menu, press 2# to set the Rx100 back into normal mode and
the joystick will then revert to pan/tilt control.

Dome Reset
This command will cause the dome to carry out a system reset, including erasing any preset positions and programming. This command must
be used with extreme caution. To activation the dome reset, the command must entered 3 times, eg for the Tx1500, press 4# 4# 4#.

Cruise
Recording: The dome has a built in cruise facility allowing the operator to record and playback a period of manual dome movement. The
exact procedure varies depending upon the control equipment and version of dome firmware. The example shown assumes that the dome is
controlled using a Tx1500.
To record the cruise, you must enter the dome menu using 1# 1# and navigate to the RECORD START entry within the CRUISE menu.
After pressing the ENTER command using 1# you must exit the dome menu using 2# to allow the joystick to be used to move the dome
around the intended area. To complete the cruise, press the Dome Menu command twice using 1# 2# to allow the joystick to be used to
navigate to the RECORD END line. Pressing the ENTER command using 1# saves the cruise. Navigate out of the menu and exit the dome
menu using 2#.
Playback: The cruise can be started by pressing the AUTOPAN key on the controller.

Return to home: Link J6/pin 4-5 if fitted will cause the dome to return to preset 8 after 5 minutes of inactivity. If function not required refit
link to J6/pin 3-4.


Speed select: Two versions of dome protocol are published. The early version has uses speeds 0 – 8 and the later version has speeds 0 – 15.
Link J6/1-2 when fitted selects the later version and removed the earlier version. If the dome speed controls are very ‘sluggish’ then try
operation with the link in the other position.

RS485 control of dome. Data rate, 9600 Baud, No parity, 8 Data bits, 1 Stop bits

Connection details:

Dome

Description

Rx100

D-

RS485 Data -

J3/C1

D+

RS485

Data+

J3/C2


Notes:

The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.
Check with the DM multiplexer manual for exact procedure for entering * commands.