Rx100 installation manual V1.17 29 Aug 08.doc

Page 18

Early dome - Set dome address to 1: 8 way switch 1 ON, 2-7 OFF. 4 way switch 1-3 ON, 4 OFF.
Later dome – Dome ID switch: 1 ON, 2-8 OFF. Duplex/Simplex switch:1-2 OFF. Dynacolor protocol S2:1-4 OFF, S1:1-3 ON

BBV Rx 100

Interface Receiver

Addendum to manual for the following domes:



Forward Vision protocol
including MIC1 300/400 series dome
and compatible equipment.

Rx100 software RX1_F1V8


Application Notes

Variable 16 speed Pan/Tilt.
Zoom/Focus
16 full scene presets
2 preset patrols
4 alarm inputs driving to preset 1 - 4

Advanced Features

Tx400

Tx1000

Tx1500 DM Mux DSL/DS2/BX2

AUTO/MANUAL FOCUS TOGGLE ‘#’ 1

‘#’ WASH

1 ‘#’

*889 002 or *889 10 10 2 (twice)

DIGITAL ZOOM ON/OFF

‘#’ 2

'#' WIPE

2 '#'

*889 003 or *889 10 10 3

MANUAL/AUTO EXPOSURE

‘#’ 3

'#' AUTOPAN

3 '#'

*889 004 or *889 10 10 4

IR FILTER IN/OUT

‘#’ 4

‘#’ LIGHTS

4 ‘#’

*889 005 or *889 10 10 5


Version V4 of software has added support for PRIVACY ZONE programming. (TX1500 keystrokes shown)
ENABLE ALL SCENE

1 ‘#’ PROGRAM 1 PRESET (Whole screen)

DISABLE ALL SCENE

1 ‘#’ PROGRAM 2 PRESET (Whole screen)

TOGGLE CURSOR ON/OFF

1 ‘#’ PROGRAM 3 PRESET

ENABLE AROUND CURSOR

1 ‘#’ PROGRAM 4 PRESET (Centre of screen)

DISABLE AROUND CURSOR

1 ‘#’ PROGRAM 5 PRESET (Centre of screen)


DM DS2 example to ENABLE ALL SCENE as privacy.
*889 10 10 2 [PRESS AND HOLD ‘PRESET’] 1 [ENTER]

RS485 control of dome using the following connections:

Rx100

Description

Dome

J3-C1

RS485

IN(A)

Yellow

J3-C2

RS485

IN(B)

White

Notes:

The alarm output relay opens for approx 5 seconds upon power up and following local alarm activation.

A local alarm opening contact will cause the dome to move to the respective preset position. After 60 seconds the dome will revert to preset patrol if the patrol
was active before the alarm occurred.

Links Function
J6/4-5

Enable datum mode: Goto preset 1 or start Patrol 1 2 minutes after last activity. J6/3-4 = Function disabled.

J6/1-2

Select datum function: Fitted = goto preset 1, Removed = start Patrol 1


TEST link when shorted will drive the dome LEFT and ZOOM IN. Removing the short will stop pan and ZOOM OUT. This is used to gain confidence that the
wiring between Rx100 and dome is correct. The GREEN DATA led will flash when a command is sent to the dome.

VERSION 6 now enables zoom proportional pan/tilt speed to improve manual control.

For correct operation, ensure that the dome/head address is set to 01.
Please contact Forward Vision for exact procedure on +44(0)870 011 3131.