Bbv rx 100, Interface receiver – Sony BBV RX100 User Manual

Page 29

Advertising
background image

Rx100 installation manual V1.17 29 Aug 08.doc

Page 29

BBV Rx 100

Interface Receiver

Addendum to manual for the following domes:


Sensormatic Speeddome

Rx100 software RX1_S3V6


Coaxial telemetry ONLY. Not twisted pair!

Application Notes


Variable speed Pan/Tilt.
Zoom/Focus, Autofocus, Iris Open/Close
7 full scene presets
2 preset patrols
4 alarm inputs driving to preset 1 – 4
Pattern 1 define – play using Autopan key

Advanced

Features

Tx1000

Tx400

DM

DS/DS2/BX2

Start/Stop PATTERN1 Definition

'#' WASH

'#' 1

*889 002 or *889 10 10 2

(Press AUTOPAN to Run Pattern1)
Dome Menu

'#' LIGHTS

'#' 4

*889 005 or *889 10 10 5


RS485 control of dome 4800 Baud, No parity, 8 data bits, 2 stop bits.

Dome Cable

Description

Rx100

RS422 IN-/Data In-

Data-(B)

J3/C1

RS422 IN+/Data In+

Data+(A)

J3/C2


Notes:

The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.

Accessing the dome menus.
Press either '#'LIGHTS , '#'4 or *889 005 key strokes to Enter Menu. Use Pan/Tilt/zoom/focus functions are then used to navigate through menu structure.
Please refer to individual dome manual for exact operation of menu.

Check with the multiplexer manual for exact procedure for entering * commands.

IMPORTANT:
Dome settings: Select dome address 01 or 001.
Communications must be 4800, N, 8, 2 – RS422, NOT SensorNet.

The interface software is based on 1997 protocol and has been tested with Ultradome IV, Ultradome VI and original Speeddome.

Link J6/1-2 used to enable/disable datum mode to start preset patrol.
Link fitted = datum disables
Link removed = datum enabled, start preset patrol after 60 seconds of inactivity