Bbv rx 100, Interface receiver – Sony BBV RX100 User Manual

Page 22

Advertising
background image

Rx100 installation manual V1.17 29 Aug 08.doc

Page 22

BBV Rx 100

Interface Receiver

Addendum to manual for the following domes:


Mark Mercer 150 and D250/500 series


Rx100 software RX1_M1V6

Application Notes

Variable speed Pan/Tilt.
Zoom/Focus override, Iris override
16 full scene presets
2 preset patrols
4 alarm inputs driving to preset 1 – 4

2 minute datum (park) mode, link selectable as either preset 1 or slow preset patrol.

Advanced Features

Tx400

Tx1000

Tx1500 DM Mux/DS/DSL/DS2/BX2 etc

Pan ‘U’-turn (180deg flip)

‘#’ 1

'#' WASH

1 ‘#’

*889 002 or *889 10 10 2

Dome Reset

‘#’ 4

‘#’ LIGHTS

4 ‘#’

*889 005 or *889 10 10 5


A slow preset patrol can be started by pressing AUTOPAN. The preset dwell is fixed at 20 seconds with a dome speed of 1.

RS485 control of dome using the following connections:

Rx100

Description

Dome

6

pin

connector

J3-C1

TX/RX-

RS485

B

Pin

4

(RED)

J3-C2

TX/RX+

RS485

A

Pin

3

(GREEN)

Notes:

The alarm output relay opens for approx 5 seconds upon power up and following a local alarm activation.

Links Function
J6/1-2

Enable 2 minute inactivity datum mode if the link is fitted.

J6/3,4,5

Select datum operation, J6/4-5 = goto preset 1, J6/3-4 = start slow preset patrol.


Only operational whilst the dome is not running a patrol.