Setting switcher GPI outputs

1

From the top menu, select Setup/Diag >GPI >SWR
GPI Out.

The SWR GPI Output menu appears. The status area
shows the GPI output ports, and the trigger type,
output timing, pulse width, and action set for the signal
to be output from each port.

2

Select the port for which you want to make the setting.

• Press directry on the list in the status area.
• Use the arrow buttons to scroll the reverse video

cursor.

• Turn the knob.

a) Select 1 to 8 for GPI ports (G-1 to G-8), and 9 to 16 for tally ports

(T1 to T8).

To change the trigger type setting
Press [Trigger Type], to display a popup window, and
select the trigger type.

(falling edge): The trigger closes the relay contacts

or causes a low output level, and this state is
maintained for the specified pulse width.

(rising edge): The trigger opens the relay contacts or

causes a high output level, and this state is maintained
for the specified pulse width.

(both edges): Each time the trigger is activated, the

relay switches between open/closed or the output level
switches between high/low.

Status: Depending on the state, the relay is switched open/

closed or the output level is switched high/low.

Disable (disabled): No output.

To change the timing setting
When the trigger type is other than [Status] or [Disable],
press [Timing] to display a popup window, and select the
timing.
Any: Output on the earliest field that can be processed.
Field 1: Output on field 1.
Field 2: Output on field 2.

Note

When the following signal formats are selected, it is not
possible to set the timing.
• 1080PsF/23.976
• 1080PsF/24
• 1080PsF/25
• 1080PsF/29.97
• 720p/59.94

To change the pulse width setting
When the trigger type is

(falling edge) or

(rising edge), turn the knobs to set the pulse width.

To change the action setting
Press [Action] to display a popup window, and select the
action.

M/E Key1 Cut

M/E K1 Cut

M/E Key2 Auto Trans

M/E K2 AT

M/E Key2 Cut

M/E K2 Cut

DSK1 Auto Trans

DSK1 AT

DSK1 Cut

DSK1 Cut

DSK2 Auto Trans

DSK2 AT

DSK2 Cut

DSK2 Cut

FTB Auto Trans

FTB AT

FTB Cut

FTB Cut

Snapshot Recall ?

b)

Snapshot

No Action

No Action

FM V Field Freeze

FM V Field

FM V Frame Freeze

FM V Frame

FM V Freeze Off

FM V Off

FM K Field Freeze

FM K Field

FM K Frame Freeze

FM K Frame

FM K Freeze Off

FM K Off

Action button

Status area display

Knob

Description

Setting
values

1 (Port)

GPI output port number
selection

1 to 16

a)

Knob

Description

Setting values

2 (Pulse Width)

Pulse width

1 to 60 (fields)

Action button

Status area display

M/E Auto Trans

M/E AT

M/E Cut

M/E Cut

P/P Auto Trans

a)

P/P AT

Advertising
This manual is related to the following products: