Gpi outputs of the control panel, Assigning gpi inputs to dcu parallel input ports – Sony MKS-2010 User Manual

Page 179

Advertising
background image

Ch
ap
te

r 9
Sys

tem Set

tings

179

Other Settings

a) 1.5 M/E panel only
b) When [Snapshot Recall ?] is selected, press [Register No] to set a register

number (1 to 99).

Setting the action when the trigger type is [Level]
When the trigger type is [Level], press [Action] to display
a popup window, then you can select the following four
actions.

When other than [No Action] is selected, you can set the
action separately for when the input is high level and when
the input is low level. To set the action when the input is
high level, press [High Level], and to set the action when
the input is low level, press [Low Level], to display a
popup window.

When [Signal Format] is selected: In the popup window,

press any of the following action buttons, to select the
action when the input goes to the high level/low level.
• 576i/50
• 480i/59.94
• 720P/59.94

• 1080i/50
• 1080i/59.94
• 1080PsF/23.976
• 1080PsF/24
• 1080PsF/25
• 1080PsF/29.97
• No Action

When [Screen Aspect] is selected: In the popup window,

press the following action buttons, to select the action
when the input goes to the high level/low level.
• 4:3
• 16:9
• No Action

When [Level Enable] is selected: In the popup window,

press the following buttons, to select the action when
the input goes to the high level/low level.
• Enable
• Disable
• No Action

Note

When using [Signal Format] and [Screen Aspect], set the
[Level Enable] GPI input to [Enable]. If this is not set to
[Enable], the GPI inputs are not valid.

GPI outputs of the control panel

The GPI outputs of the control panel are fixed as follows,
so you need not make settings for them.

Assigning GPI inputs to DCU parallel input
ports

You can assign GPI inputs to DCU parallel input ports
which are not being used for tally external box input and
tally enable input.

See “Tally Setup (System Tally Menu)” (page 182) for
more information about tally external box input and tally
enable input.

1

From the top menu, select Setup/Diag >GPI >DCU In
Config.

The DCU Input Config menu appears.

P/P Auto Trans

a)

P/P AT

P/P Cut

a)

P/P Cut

M/E Key1 Auto Trans

M/E K1 AT

M/E Key1 Cut

M/E K1 Cut

M/E Key2 Auto Trans

M/E K2 AT

M/E Key2 Cut

M/E K2 Cut

DSK1 Auto Trans

DSK1 AT

DSK1 Cut

DSK1 Cut

DSK2 Auto Trans

DSK2 AT

DSK2 Cut

DSK2 Cut

FTB Auto Trans

FTB AT

FTB Cut

FTB Cut

Snapshot Recall ?

b)

SnapShot

No Action

No Action

FM V Field Freeze

FM V Field

FM V Frame Freeze

FM V Frame

FM V Freeze Off

FM V Off

FM K Field Freeze

FM K Field

FM K Frame Freeze

FM K Frame

FM K Freeze Off

FM K Off

Macro Take

Macro

Action button

Status area display

No Action

No Action

Signal Format

Format

Screen Aspect

Aspect

Level Enable

Enable

Action button

Status area display

Port number

Action

GPI-1

Error Status

GPI-2

No Action

GPI-3

No Action

GPI-4

No Action

GPI-5

M/E Key1 On Status

GPI-6

M/E Key2 On Status

GPI-7

DSK1 On Status

GPI-8

DSK2 On Status