DataNET Troubleshooting Guide,

Continued

Configuration
Parameter Errors

The device may have an invalid or duplicate IP address, Subnet mask or
iproute. Each ANCB must have a unique IP address. Verify the
configuration parameters by connecting a PC serial port to the
Configuration Port, Logging in and typing config display.

local> config display

Config:

Device

ANCB_DN

address ip

172.16.9.239

netmask

255.255.0.0

address ethernet

00.c0.c9.00.d2.3b

iproute

0.0.0.0

time server ip

0.0.0.0

port1

DataNET Copper

port2

DataNET Copper

Device ID

The ANCB/DN device id is automatically assigned and is not user
configurable as it is on the DataNET Hub. Th ANCB/DN device ID is
automatically set to the board IP address at power up or reset. :

Broadcast Status
Information

The Advance Network device periodically broadcast their status for
diagnostic and network routing purposes.