3-9. Mounting

(1) To install the indoor unit, mount the indoor unit onto

the 2 tabs on the upper part of the rear plate.

(2) Hold down the air discharge outlet and press the

lower part of the indoor unit until it clicks to secure-

ly fasten to the 2 tabs on the lower part of the rear

plate. (Fig. 33)

For tubing, choose either the right or left tubing direc-

tion and follow the steps below. Also, extend the sup-

port on the back of the indoor unit as a stand to make

your work easier. (Fig. 34)

Right-side tubing

(1) Shape the refrigerant tubing so that it can easily go

into the wall hole. (Fig. 35)

(2) Push the wiring, refrigerant tubing, and drain hose

through the hole in the wall. Adjust the indoor unit

so it is securely seated on the rear panel. (Fig. 36)

(3) Carefully bend the tubing (if necessary) to run

along the wall in the direction of the outdoor unit

and then tape as far as the fittings. (See Caution

on page 17.) The drain hose should come straight

down the wall to a point where water runoff won’t

stain the wall.

(4) Connect the refrigerant tubing to the outdoor unit.

(After performing a leak test on the connecting part,

insulate it with the tubing insulation (Fig. 37a)).

Also, refer to Section 5-4. Connecting Tubing

between Indoor and Outdoor Units.

(5) Assemble the refrigerant tubing, drain hose, and

conduit (including inter-unit wiring) as shown in

Fig. 37b.

NOTE

Cover

Refrigerant
tubing

Rear panel

Drain hose

Inter-unit
wiring

Fig. 35

Fig. 36

Insulation

Fig. 37a

Fig. 37b

Push

Fig. 33

Stand

Fig. 34

Refrigerant tubing

Drain hose

Conduit

Inter-unit wiring

01-385 AirCon 12/11/01 4:42 PM Page 13