1. General

This booklet briefly outlines where and how to install the

air conditioning system. Please read over the entire set

of instructions for the indoor and outdoor units and

make sure all accessory parts listed are with the system

before beginning.

1-1. Tools Required for Installation (not supplied)

1. Standard screwdriver

2. Phillips head screwdriver

3. Knife or wire stripper

4. Tape measure

5. Carpenter’s level

6. Sabre saw or key hole saw

7. Hacksaw

8. Core bits

9. Hammer

10. Drill

11. Tube cutter

12. Tube flaring tool

13. Torque wrench

14. Adjustable wrench

15. Reamer (for deburring)

1-2. Accessories Supplied with Unit

Table 1

1-3. Optional Copper Tubing Kit

Copper tubing for connecting the outdoor unit to the

indoor unit is available in kits which contain the narrow

and wide tubing, fittings and insulation. Consult your

nearest sales outlet or A/C workshop.

1-4. Type of Copper Tube and Insulation Material

If you wish to purchase these materials separately from

a local source, you will need:

1.

Deoxidized annealed copper tube for refrigerant

tubing as detailed in Table 2.

When cutting tubing, add approximately 12" to 16"

(30 cm to 40 cm) to each tube length to reduce

vibration between the air conditioning units.

Table 2

2.

Foamed polyethylene insulation for the specified

O.D. copper tubes as required to precise length of

tubing. Wall thickness of the insulation should be

not less than 0.3 in. (8 mm).

1-5. Field Wiring

Use insulated copper wire for field wiring. Wire size

varies with the total length of wiring. Refer to 3-6. Wiring

Instructions for details.

Parts

Figure

Q’ty

Parts

Figure

Q’ty

Rawl plug

12

12

Tapping
screw

Truss-head
Phillips
5/32

Ч

5/8" (4

Ч

16 mm)

2

1

1

AAA alkaline
battery

1

1

Parts

Figure

Q’ty

Remote
control unit

Drain hose
adapter

Hex
wrench

*

Remote
control
holder

CAUTION

Check local electrical codes

and regulations before

obtaining wire. Also, check

any specified instructions or

limitations.

Narrow Tube

Wide Tube

Model

Outer Dia.

Thickness

Outer Dia.

Thickness

6.35 mm (1/4")

0.8 mm (0.0314")

9.52 mm (3/8")

0.8 mm (0.0314")

CH0951

6.35 mm (1/4")

0.8 mm (0.0314")

12.7 mm (1/2")

0.8 mm (0.0314")

CH1251

6.35 mm (1/4")

0.8 mm (0.0314")

15.88 mm (5/8")

1.0 mm (0.0394")

CH1852

*

Packed in the outdoor unit.