4. How to Install the Outdoor Unit

First refer to Section 2. Installation Site Selection.

4-1. Wiring Instructions for the Outdoor Unit

Regulations on wire size differ from locality to locality. For field

wiring requirements, please refer to your local electrical

codes. Make sure that the installation fully complies with all

local and national regulations.

(1) Remove access panel. (Fig. 41)

(2) Connect the power line according to the drawing on the

panel side.

(3) Be sure to size each wire allowing approx. 4 in. (10 cm)

longer than the required length for wiring. Store excess

wiring inside the cabinet.

(4) When connections are completed, check that all connec-

tions are correct as shown in the wiring system diagram

on panel side.

(5) Be sure to ground the unit according to your local codes.

Lock nut

Terminal
block

Access panel

Control line
(Sheath cable)

Power line
(Conduit)

Plug

Conduit
plate

Power supply
(Conduit)

Fig. 41

Examples of Incorrect Wiring

The following are examples of improper wiring that result in system misoperation. You should confirm that you have

wired the units correctly before beginning the test run.

CAUTION

Problem 1

Short circuit will occur after approx.

3 minutes and the power circuit fuse

blows.

Problem 3

Compressor will not start; only indoor unit will operate.

Problem 2

Air conditioner will not operate.

1

2

3

G

Disconnect
switch

Indoor unit

Grounding line

G

(D)

Outdoor unit

1

2

3

1

2

3

G

Disconnect
switch

Indoor unit

Grounding line

G

(E)

Outdoor unit

1

2

3

1

2

3

G

Disconnect
switch

Indoor unit

Grounding line

1

2

3

G

(A)

Outdoor unit

1

2

3

G

Disconnect
switch

Indoor unit

Grounding line

G

(B)

Outdoor unit

3

1

2

1

2

3

G

Disconnect
switch

Indoor unit

Grounding line

G

(C)

Outdoor unit

3

1

2

CAUTION

Apply sealer (putty, etc.) to

the gap between the sheath

cable and the hole of the

conduit plate to prevent

water from entering.