Sony UP-50 User Manual

Page 75

Advertising
background image

75

Installation and Adjustment

a) This selector is supplied with models other than UP-51MDU. Set the NTSC/PAL selector to your

TV system. To switch the TV system, turn the power off once, then change the setting. If you
change the setting with the power on, this mode will not be switched.

b) Two kinds of 75-ohm termination switches are provided; one is for the RGB input and the other is

for the composite video signal. Normally set this switch to ON. Set it to OFF if the level of the
input signal drops because the signal is divided to additional video equipment other than the
printer.

Making Connections for Viewing Images to be Printed

Connect a video monitor to view stored images and to check those to be printed.
Connect the required video monitor which will be used in actual printing, using the
following diagram as a guide.
Before connecting the video equipment, see “Important safeguards/notices for use
in the medical environments” for UP-51MD/51MDU/51MDP on page 2.

to S-VIDEO
OUTPUT

to VIDEO OUTPUT

to RGB/SYNC OUTPUT

b)

to S-VIDEO
input
connector

to composite
video input
connector

to RGB input
connectors

Video monitor

to AC IN

AC power cord
(supplied)

to wall outlet

75-ohm coaxial
cable with BNC
connectors

Connecting cable (with
DIN 4-pin connectors)
YC-15EV

NTSC/PAL selector

a)

75-ohm coaxial
cable with BNC
connectors

NTSC PAL

a) This selector is supplied with models other than UP-51MDU. Set the NTSC/PAL selector to your

TV system. To switch the TV system, turn the power off once, then change the setting. If you
change the setting with the power on, this mode will not be switched.

b) See “When connecting the video monitor to the RGB SYNC OUTPUT connectors” on the next

page.

Advertising
This manual is related to the following products: