Kodak 6B6640 User Manual

Page 30

Advertising
background image

Troubleshooting

2-14

March 2001

<27>

BAD_PATCH

If the Pattern Recognition comparison window is set to 0 or 1, this error
may result when a single patch on the strip is bad due to dirt, smears,
creases, etc. (See explanation of CW command for more information.)

<30>

BAD_STRING_LENGTH

A strip definition string received as part of the DS (Define Strip) RCI
command did not contain the correct number of characters.

<31>

BAD_CHARACTER

A non-printable character was received in one of the name fields (strip
name or pass name). Printable characters are in the range 0x20 to 0x7E,
inclusive.

<32>

BAD_MEAS_TYPE

The value for the measure type field was greater than 3. Valid values are
0 through 3.

<33>

BAD_COLOR

The value for the color field was greater than 9.

<34>

BAD_STEPS

The value for the number of steps was greater than 72.

<35>

BAD_STOP_LOCATION

The value for the guide setting was less than 4 or greater than 30.

<36>

BAD_OUTPUT_TYPE

The value for the output type was greater than 5.

<37>

MEMORY_ERROR

The definition could not be stored.

<38>

BAD_N_FACTOR

The n-factor (used in Dot calculations) is either less than 0500 (0.500) or
greater than 4500 (4.500).

<39>

STRIP_DOESNT_EXIST

The SD command was issued and the requested strip does not exist.

<3A>

BAD_MIN_MAX_VALUE

The value for the min/max field was greater than 4.

<40>

BAD_SERIAL_NUMBER

An attempt was made to redefine one of the stored serial numbers with a
number containing one or more invalid digits.

Code

Message

Explanation