GETTING STARTED

In the next menu press the

or

button to defi ne the

measurement unit the level is to be indicated. Press

to

keep the current setting.

The next menu prompts you to set the mute function using the

or

button. If you select ON, the MSK 125 is switched

to silent as long as the incoming signal on the RF input is below

30 dBµV. Press the

button to keep the desired setting.

After you have set the low-level mute you automatically exit the
third setup menu.

2. Setup menu

3. Setup menu

DEFAULT SETUP SETTINGS AT TIME OF SHIPMENT

Parameter

Setting

LNB DC

OFF

LEVEL

dBµV

LOW LEVEL MUTE

ON

MAINS AND BATTERY OPERATION

The MSK 125 can be operated on the mains or by means of its
integrated battery.

MAINS OPERATION

Remove the supplied AC power unit (100 V ... 250 V) from the
packaging and connect it to the device and mains. The integrated

lithium-ion battery and the green LED next to the

button

indicate the external power supply.
For mains operation use only the supplied power unit. The
power unit is connected to the XLR power supply socket on the
left side of the device.
For longer times the devices is not used it should be connected
to the mains occasionally (trickle charge)

Note: A 12 V vehicle supply cable can be obtained through
our customer service (company ESC, address see page 67)
(order no.: 19700841BF).