COMMAND OVERVIEW FOR ADDRESS BYTE

Hex Byte Description

00

All devices

10

Every LNB, matrix or SMATV

11

LNB

12

LNB with loop-through

14

Matrix (switcher)

15

Matrix (switcher) with loop-through

18

SMATV

20

Every polarizer

21

Maximum turn (full skew) in linear polarisation

22

Stepwise polarizer adjustment

30

Every positioner

31

Polar/Azimuth positioner

32

Elevation positioner

33

Combined positioner

34

LNB positioner

40

Installation help

41

Signal strength adjustment help

60

Reserved for assigned addresses

70

“Intelligent slave interface” for “Proprietary Multi-Master
bus”

71

Interface for participants and controlled head end

Fx

OEM expansion

SAT

COMMAND OVERVIEW FOR FRAMING BYTE

HEX
Byte

Description

E0

Master command, one-time transmission

E1

Master command, recurring transmission

E2

Master command, expecting response, fi rst transmission

E3

Master command, expecting response, recurring transmission

E4

Response from Slave, “OK”, no errors detected

E5

Response from slave, command not supported by slave

E6

Response from Slave, parity error detected

E7

Response from slave, command not recognised