Maintenance – Kathrein MSK 125 User Manual

Page 66

Advertising
background image

66

MAINTENANCE

The device maintenance is basically limited to outside cleaning.

DEVICE CALIBRATION

The caliber interval depends on the use and load and should be between one and two years. Calibration
can be done by Kathrein customer service. For address see next page.

OUTSIDE CLEANING

For outside cleaning a soft cloth, non-linting duster or paint brush is recommended. For strong
contamination spirit or mild soapsuds can be used as well. Never use any dissolvers like nitro-cellulose
combination thinner, acetone, etc., as these may damage the plastic parts and labels.

INSIDE CLEANING

Caution!

Since inside cleaning requires opening the device, such activity must be done by authorized personnel
only. The device should be dust-cleaned inside in regular intervals, app. every one to two years, to
ensure optimum ventilation. Cleaning intervals are based on the daily operating time and the dust volume
in operating rooms. For inside cleaning remove the back wall or the control part. Dust deposits can
be removed using a brush or grease-free compressed air.

FUNCTIONAL TEST

We recommend to check the specifi ed required data in appropriate time intervals. For data and tolerances
please see the Technical Specifi cation.

REQUIRED MEASUREMENT TOOLS

- TV/SAT signal generator to check level accuracy and analogue measurements and demodulations.
- DVB signal generator to check level accuracy and digital measurements and demodulations.

CHANGING THE BATTERY

• Screw off handle
• Remove plastic sub-shell
• Remove metal battery cover at bottom of device
• Remove battery
• Unplug battery
• Insert the new battery, connect it and reassemble the device in the

reverse order

• Note disposal instruction on page 2.

STORAGE

The storage temperature range of the device is -20 °C ... +85 °C.
Please keep the device clear of dust and humidity.