FM MEASUREMENT

LEVEL OVERFLOW AND UNDERFLOW

At a level < 30 dBµV the display indicates an underfl ow.
LC display:
• Frequency: 104.8 MHz
• Operating mode: FM
• Level: underfl ow
At a level > 120 dBµV the LC display indicates an overfl ow.
LC display:
• Frequency: 104.8 MHz
• Operating mode: TV
• Level: Overfl ow

FINDING INDIVIDUAL RECEPTION FREQUENCIES

The

function allows you to adjust the antenna to the

maximum reception signal. The display indicates the reception in the

form of an increasing or decreasing bar. The

buttons

allow you to set the measurement range to three sensitivity levels.
The bearing sound enables you to monitor the level. The pitch
of the bearing sound is proportional to the received signal level.
The volume of the bearing sound can be adjusted using the

volume buttons.

COMMAND OVERVIEW FOR “FIND”

Switch to “Find” mode

Switch the measurement range, the bar graph

and the bearing sound:

Level range 1: Large input levels

Level range 2: Medium input levels

Level range 3: Small input levels

Exit this mode

LC display:
• Level range 2: Medium input level
• Operating mode: FM
• Bar graph display

Example

Launching the “Find level” function: Press the

button

Turn the antenna until the bar display reaches its maximum.
If necessary, decrease or increase the sensitivity using the

buttons. Turn the antenna until you have reached the

maximum level.

To exit “Find level”: Press the

button.