Level measuring component

Measuring range

dBµV

30 ... 120

Measurement accuracy

dB

± 2

Measurement bandwidth

SAT: 6 MHz

SAT-DVB: 6 MHz

TV: 250 kHz

TV-DVB: 6 MHz

FM: 250 kHz

Detector

SAT: Mean value display

TV: Peak value display

FM: Mean value display

BER/MER/carrier offset measurement

DVB-S(2)/-C/-T/-H

Display

TV monitor

TFT 5.7“ colour display, 640 x 480 pixels, transfl ective

LCD Display

Alphanumeric (131 x 22 pixels), illuminated, transfl ective

Sat Finder (acoustic)

Level-dependent beep

Supply voltages

Power supply

V/Ah

11.1/6.45 Li-ion battery

Mains supply

V AC

100 ... 240 (via external AC/DC power unit)

Auto-operation

DC

Optionally via 12 Volt vehicle supply cable (BN: 19700841BF)

Remote feed voltage

V

0, 5 ... 20

Remote feed current

mA

Max. 600

LNB control

kHz

22, DiSEqC

TM

1.0, Simple DiSEqC

TM

Connections

RF input/impedance

-/Ω

F coaxial socket (with BNC adapter)/75

AV input/output

SCART (CVBS, audio)

Head phones socket

mm

3.5 jack

USB port

Type 2 socket

Memory card

SD (1 GB max.)

Serial interface

RS 232, Sub-D, 9-pole

CI interface

PCMCIA

DC voltage supply

DC-XLR socket

General

Dimensions (L x W x H):

mm

297 x 258 x 100

Weight

kg

Approx. 3.8

Safety standards

CE marking

Protection class I (AC/DC power unit)

Temperature range

°C

Operation: +5 to +45

Storage: -20 to +85

TECHNICAL DATA