Tv measurement, Cable analogue” level measurement – Kathrein MSK 125 User Manual

Page 37

Advertising
background image

37

COMMAND OVERVIEW FOR TV FREQUENCY ENTRY

Switch to desired TV reception

Channel/frequency

switch

...

Enter

frequency

Confi rm entry

and

Change frequency in intervals

or

Example

To enter the frequency 175.25 MHz:

Press

(calling up the frequency menu)

Then

(frequency entry)

LC display:
• Frequency: 175.25 MHz
• Level: 65.0 dBµV
• Operating mode: Analogue cable TV

TV MEASUREMENT

After calling up the frequency menu for the fi rst time you have to
enter the digit order for another frequency entry.
The most recent frequency setting remains even after you switch
the MSK 125 off if it has been entered with digits and confi rmed by

pressing

.

Note

“CABLE ANALOGUE” LEVEL MEASUREMENT

After you have set a channel or frequency the level is measured
automatically and indicated on the LC display in dBµV or dBmV
(depending on the device confi guration). The input level can be
measured in the range of 30 dBµV to 120 dBµV (-30 dBmV to
60 dBmV).

LC display:
• Channel: CH 05
• Operating mode: Analogue cable TV
• Measured level: 86.5 dBµV

Please note that the points before and after the channel number
refer to the precisely set channel:
CH: .10. or CH: S.04.
If you enter the frequency outside the valid channel raster, the
channel is displayed without points:
CH: 10 or CH: S 04

Advertising