Flow, Port number, 3 flow -17 – Lantronix Device Server UDS 10 User Manual

Page 57: 4 port number -17, Table 8 - flow control options -17

Advertising
background image

Configure

UDS-10 User Guide

3-17

3.6.3 Flow

Flow control sets the local handshake method for stopping serial input/output.

Table 8 - Flow Control Options

Flow Control Option

Hex

No flow control

00

XON/XOFF flow control

01

Hardware handshake with RTS/CTS lines

02

XON/XOFF pass characters to host

05

3.6.4 Port Number

The setting represents the source port number in TCP connections, and is the number used to
identify the channel for remote initiating connections. Default setting for Port 1 is 10001.
Range: 0-65535 except for the following reserved port numbers:

Port Numbers

Reserved for

1 – 1024

Reserved (well known ports)

9999

Telnet setup

14000-14009

Reserved

30718 Reserved

(77FEh)

10000-10999

Recommended ports, should be used for DeviceComm
Manager (COM1-COM256) or direct socket connections

The port number functions as the TCP/UDP source port number for outgoing packets.
Packets sent to the unit with this port number are received to this channel. The port number
selected is the Incoming TCP/UDP port and Outgoing TCP/UDP source port. Port 0 is used
when you want the outgoing source port to change with each connection.