Firmware

UDS-10 User Guide

4-5

4. In

the

Destination File field, enter the current internal operational code or WEB5 for

the internal Web interface. (For UDS-10-IAP, AQ = Standard Tunnel, AM = Modbus,
AD = DF1. For UDS-10, 3Q = Standard Tunnel)

5. In

the

Remote Host field, enter the IP address of the unit being upgraded.

6. Click

the

Put button to transfer the file to the unit.

Figure 18 - TFTP Dialog Box

The unit performs a power reset after the firmware has been loaded and stored.

4.2.3 Via Another Unit

To distribute firmware to another unit over the network:
1. Enter the host unit's Monitor Mode (see Monitor Mode on page 7-1).
2. Send the firmware to the receiving unit using the SF command, where x.x.x.x is the

receiving unit's IP address.

SF x.x.x.x

The receiving unit performs a power reset after the firmware has been loaded and stored.
Note: You can only update your unit 's internal Web interface using TFTP or Device
Installer.