8.3.7 Flush Mode (Buffer Flushing)

Using this parameter, you can control line handling and network buffers with connection
startup and disconnect. You can also select between two different packing algorithms. Use
the following table to select Flush Mode options:

Table 29 - Flush Mode Options

Function

7

6

5

4

3 2 1

0

Input Buffer (Serial to Network)

Clear with a connection that is initiated from the
UDS to the network

1

Clear with a connection initiated from the network
to the UDS

1

Clear when the network connection to or from the
UDS is disconnected

1

Output Buffer (Network to Serial)

Clear with a connection that is initiated from the
UDS to the network

1

Clear with a connection initiated from the network
to the UDS

1

Clear when the network connection to or from the
UDS is disconnected

1

Alternate Packing Algorithm (Pack Control)

Enable

1

Note: See Table 35 - Binary to Hexadecimal Conversion Table.

8.3.8 Pack Control

Alternate packing algorithm settings are enabled in Flush Mode. Use the following table to
select Pack Control options:

Table 30 - Pack Control Options

Option

7 6 5 4 3 2 1 0

Idle Time

Force

transmit:

12ms

0 0

Force

transmit:

52ms

0 1

Force

transmit:

250ms

1 0

Force

transmit:

5sec

1 1

Trailing

Characters

None

0 0

One

0 1

Two

1 0

Send

Characters

Sendchars

Define

2-Byte

Sequence

1

Send Immediately After Sendchars

1