Connect mode, 5 connect mode -18, Table 9 - connect mode options -18 – Lantronix Device Server UDS 10 User Manual

Page 58

Advertising
background image

Configure

3-18

UDS-10 User Guide

3.6.5 Connect Mode

Connect Mode defines how the unit makes a connection, and how it reacts to incoming
connections over the network. Enter Connect Mode options in hexadecimal notation.
Note: See Table 35 - Binary to Hexadecimal Conversion Table.

Table 9 - Connect Mode Options

Connect Mode Option

7

6

5

4

3

2

1

0

Incoming Connection
Never

accept

incoming

0 0 0

Accept

incoming

with

DTR

0 1 0

Accept

unconditional

1 1 0

Response
Nothing

(quiet)

0

Character response (C=connect,
D=disconnect, N=unreachable)

1

Startup
No active startup

0

0

0

0

With any character

0

0

0

1

With active DTR

(1)

0 0 1 0

With CR (0x0D) only

0

0

1

1

Manual

connection

0 1 0 0

Autostart

0 1 0 1

Datagram Type
Directed

UDP

1 1 0 0

Modem Mode
Full

Verbose

1 0 1 1 0

Without

Echo

0 0 1 1 0

1-character

Response

1 0 1 1 1

Manual Connection: When you use manual connection, you are not required to enter the
entire IP address if the IP is already configured as the remote IP address in the unit. For
example, if the remote IP address already configured in the unit is 129.1.2.3, then an example
command string would be C3/7. (This would connect to 129.1.2.3 and port 7.) You may also
use a different ending for the connection string. For example, C50.1/23 would connect you to
129.1.50.1 and port 23.