Step 8 connect battery pack – LSI MegaRAID Enterprise 1600 User Manual

Page 78

Advertising
background image

MegaRAID Enterprise 1600 Hardware Guide

64

Step 8 Connect Battery Pack,

Continued

Configure Battery Backup After installing the MegaRAID controller and booting, press <Ctrl> <M>. Choose the

Objects menu. Select Battery Backup. The following menu displays:

Menu Item

Explanation

Battery Pack

PRESENT will appear if the battery pack is properly installed;
ABSENT if it is not.

Temperature

GOOD appears if the temperature is within the normal range. HIGH
appears if the module is too hot.

Voltage

GOOD appears if the voltage is within the normal range. BAD
appears if the voltage is out of range.

Fast
Charging

COMPLETED appears if the fast charge cycle is done. CHARGING
appears if the battery pack is charging.

No. of
Cycles

This must be configured. When first installing a battery pack, set the
Charge Cycle to 0. The screen below appears when you select No. of
Cycles. Choose YES to reset the number of cycles to zero.

After 1100 charge cycles, the life of the battery pack is assumed to
be over and you must replace the battery pack.

Advertising