Lenovo TS100 User Manual

Page 255

Advertising
background image

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See Chapter 3, “Parts listing, ThinkServer TS100 Machine Types 6431, 6432, 6433, and 6434,” on page 37
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

System-error log message

Action

Flash of x by y via z was successful.w

Information only.

Flash of x via z failed for user z...z

Information only.

Flash succeeded for x (address: y)

Information only.

Hard Drive x Fault

1. Run the diagnostic programs.

2. Replace hard disk drive x.

3. Replace the following component, depending on the server

model:

v

Hot-swap models: Hard disk drive backplane

v

Simple-swap models: Hard disk drive x cable

Hard drive x removal detected.

Reseat the following component, depending on the server model:

v

Hot-swap and simple-swap models: Hard disk drive x

Internal Error CPU Fault

Information only. If the message remains:

1. (Trained service technician only) Reseat the microprocessor.

2. (Trained service technician only) Replace the microprocessor.

Invalid userid or password received. Userid is w,
x, y, z

Information only.

LAN: Command Mode tamper triggered.
Possible break in attempt

Information only.

LAN: Telnet tamper triggered. Possible break in
attempt

Information only.

LAN: Web Server tamper delay triggered.
Possible break in attempt

Information only.

LAN: Ethernet interface is no longer active

Information only.

LAN: Ethernet interface is now active

Information only.

No ISMP Gateway defined for the interconnect
network. RSA x is Assuming the Gateway

Information only.

OS Watchdog response disabled by x

Information only.

OS Watchdog response enabled by x

Information only.

PFA Alert, see preceding error in system error
log

Information only. See the preceding entry in the system-error log.

Possible ASM reset occurred -- reason unknown Information only.

Power off

Information only.

Power on

Information only.

PPP[xxx] PPP-Cfg, Local-
IP@=aaa.aaa.aaa.aaa, Remote-
IP@=bbb.bbb.bbb.bbb NetMsk=ccc.ccc.ccc.ccc,
Auth=ddd

Information only.

PPP_1:Client Connected at xxx bps

Information only.

PPP_1:User requested to abort PPP interface

Information only.

Chapter 5. Diagnostics

237

Advertising
This manual is related to the following products: