Error logs – Lenovo TS100 User Manual

Page 151

Advertising
background image

Error logs

The server generates three error logs:

v

POST error log

This log contains the three most recent error codes and messages that were
generated during POST.

v

System-event/error log

This log contains messages that were generated during POST and all system
status messages from the service processor.

v

BMC system event log

This log contains messages that were generated by the mini-BMC controller.

The system event/error log and mini-BMC system event log are limited in size.
When these logs are full, new entries will not overwrite existing entries; therefore,
you must periodically clear them through the Configuration/Setup Utility program
(the menu choices are described in the User Guide). When you are troubleshooting
an error, be sure to clear both logs so that you can find current errors more easily.

Important: After you complete a repair or correct an error, clear the mini-BMC
system-event log to turn off the system-error LED on the front of the server.

Entries that are written to the system-event/error log and mini-BMC system event
log during the early phase of POST show an incorrect date and time as the default
time stamp; however, the date and time are corrected as POST continues.

Each system-event/error log entry is displayed on its own page. To move from one
entry to the next, use the Up Arrow (↑) and Down Arrow (↓) keys.

You can view the contents of the POST error log and the system-event/error log
from the Configuration/Setup Utility program. You can view the contents of the
Diagnostics error log from the diagnostic programs on the Diagnostics CD. For
more information about the diagnostic programs, see “Diagnostic programs and
messages” on page 163.

Viewing error logs from the Configuration/Setup Utility program

For complete information about using the Configuration/Setup Utility program, see
the User Guide.

To view the error logs from the Configuration/Setup Utility program, complete the
following steps:

1. Turn on the computer.

2. When the prompt Press F1 for Configuration/Setup is displayed, press F1.

3. Use one of the following procedures:

v

To view the POST error log and system-event/error log, select Event/Error
Logs
System Event/Error Log.

v

To view the BMC system-event log, select Advanced Setup Baseboard
Management Controller (BMC) Setting
BMC System Event Log.

Viewing the mini-BMC system-event log from the diagnostic
programs

The BMC system-event log that is generated by the mini-BMC controller contains
the same information, whether it is viewed from the Configuration/Setup Utility
program or from the diagnostic programs.