10

assembly. Check for damaged or torn belting. Check

conveyor shaft bearings for damage or excessive wear.

Repair or replace conveyor components as needed.

Conveyor speed varying or

intermittent

Power supply

Check for a steady 120VAC supply to the conveyor

control. If voltage is not steady, trace back to power

supply.

Control, conveyor

Check for a steady DC voltage output at terminals A+

and A-. If voltage is not steady, proceed. Check for

5 VDC output from the conveyor control at terminals

+5V(red) and COM (black). If there is no voltage output,

replace the conveyor control. If there is DC output,

proceed.

Motor, conveyor

Check conveyor motor and gearbox for any visible

damage. If there is apparent damage, repair or replace

conveyor motor. Check motor brushes for excessive or

abnormal wear. Replace motor brushes as needed.

Hall effect sensor/magnet

Check to be sure that the Hall effect sensor and

magnet are mounted on the motor. Check for any

visible damage to the Hall effect sensor and magnet. If

there is visible damage, repair or replace as needed. If

there is no visible damage, check for a frequency

output from the hall effect sensor at terminals SIG

(white) and COM (black).

Readings should be as follows:

2:15 cook time 56 Hz. approx.

5:00 25 Hz. approx.

10:00 13 Hz. approx.

16:00 8 Hz. approx.

If these readings are not achieved, replace the Hall

effect sensor/magnet