Oven will not heat

Gas supply

Check for adequate gas supply to oven.

Manual gas shut off valve

Check to see that the manual gas shut off valve is

open. Also, check flexible gas line connection for any

damage.

Main fan motor

Check for main fan operation. If it is not operating, refer

to “Oven fan will not run”.

Relay, main fan

Check for supply voltage to relay terminal #13. If

voltage is not present, trace wiring back to power

supply. If voltage is present, check for supply voltage at

terminal #14. If there is no voltage at terminal #14, and

the relay is energized, replace the main fan relay.

Fuse, 2 Amp, control (F8)

Check, replace if necessary.

Fuse holder

Check, replace if necessary.

Switch, oven fan

Check for supply voltage to the switch, if no voltage is

present, trace wiring back to the main fan relay. Check

continuity between switch terminals. Replace switch as

needed.

Switch, burner

Check for supply voltage to the switch, if no voltage is

present, trace wiring back to the oven fan switch.

Check continuity between switch terminals. Replace

switch as needed.

Air pressure switch

Check for supply voltage to the air pressure switch. If

no voltage is present, trace wiring back to burner

switch. This normally open switch should close when

the main fan is activated. Check air switch tube for

blockage or any obstructions, repair as needed. Refer

to the “Removal and installation” section for proper

adjustment of air pressure switch. Replace air pressure

switch as needed.

Thermostat, hi-limit

Terminals are normally closed. If open, reset and test

oven for proper operation. If thermostat will not hold for

maximum oven temperature, and oven is not exceeding

temperature control setting, check for proper location of

capillary tube in the oven cavity. If above checks okay,

replace hi-limit thermostat.

Burner control

Check for supply voltage to the burner control at

terminals #1 and #3. If no voltage is present, trace

wiring back to the hi-limit thermostat. If voltage is

present, check for supply voltage at pins #8 and #3

(burner blower motor). If voltage is not present, replace

burner control. If voltage is present, proceed.

Motor, burner blower

Check for supply voltage to the burner blower motor. If

no voltage is present, trace wiring back to the burner

control. If voltage is present, and the motor is not

turning, check for opens, shorts or grounds.

WITH POWER OFF: Check for locked rotor.

Replace burner blower motor as needed.

Air pressure switch

(burner motor)

Check for supply voltage at the COM terminal on the air

pressure switch. If no voltage is present, trace wiring

back to burner control. If voltage is present, check for

supply voltage switching to the NO terminal on the air

pressure switch. If the burner blower motor is running,

but voltage is not switching to the NO terminal of the air

pressure switch, check air switch tube for blockage or

any obstructions, repair as needed. Refer to the

“Removal and installation” section for proper

adjustment of air pressure switch. Replace air pressure

switch as needed.