Impinger X2 – Analog Service Manual – Dom & Int’l

9

Temperature regulation valve If 120VAC is present on the electronic temperature

control, terminal #13 to neutral, check for voltage at

temperature regulation valve. If no voltage is present,

trace wiring back to electronic temperature control. If

voltage is present, listen for valve to open and close.

Also check for opens or shorts in the operating coil.

Replace temperature regulation valve as needed.

Intermittent heating

Thermal/Overload of main fan

and burner blower motors

The main fan motor and burner blower motor are

equipped with internal thermal protection and will cease

to operate if overheating occurs. As the motors over-

heat and then cool, this will cause the units to cycle on

and off intermittently. Improper ventilation or lack of

preventive maintenance may cause this. Also, most of

the problems listed under “Oven will not heat” can

cause intermittent failure.

Conveyor will not run

NOTE: The ovens may contain two, three or four conveyor drive systems using like

components. The trouble shooting sequence will be the same for each of the conveyor

drive systems

Power supply

Check circuit breakers, reset if required. Check power

plug to be sure it is firmly in receptacle. Measure

incoming power, call power co. if needed.

Switch, oven fan

Check continuity between switch terminals. Replace

switch as needed.

Relay, main fan

Check for 120VAC supplied to relay terminal #13. If

voltage is not present, trace wiring back to power

supply. If voltage is present, check for 120VAC at

terminal #14. If there is no voltage at terminal #14, and

the relay is energized, replace the main fan relay.

Fuse, 2 Amp

Check, replace if necessary.

Fuse holder

Check for 120VAC supplied to fuse holder. If no voltage

is present, trace wiring back to main fan relay. Check

fuse holder, replace if necessary.

Switch, conveyor

Check for 120VAC supplied to conveyor switch. If no

voltage is present, trace wiring back to fuse holder.

Check continuity between switch terminals. Replace

switch as needed.

Control, conveyor

Check for 120VAC supplied to conveyor control at

terminals #1 (AC) and #2 (AC). If no voltage is present,

trace wiring back to conveyor switch. If AC voltage is

present, check for DC voltage output at terminals #3

(A-) and #4 (A+). If there is AC voltage in, but no DC

voltage out of the conveyor control. Replace the

conveyor control. If there is D.C. voltage output,

proceed.

Fuse, 2 Amp

Check, replace if necessary.

Fuse holder

Check for D.C. voltage supplied to fuse holder. If no

voltage is present, trace wiring back to conveyor

control. Check fuse holder, replace if necessary.

Switch, conveyor reversing

Check for D.C. voltage supplied to the reversing switch.

If no voltage is present, trace wiring back to the fuse

holder. Check continuity between switch terminals.

Replace switch as needed.

Conveyor motor

Check for D.C. voltage to the conveyor motor. If no

voltage is present, trace wiring back to the reversing

switch. If voltage is present and the motor will not run,

check the motor windings for opens or shorts. Check

motor brushes for excessive wear. Replace motor

brushes as needed.

If any of the above fails, replace conveyor motor.

Conveyor

Check for any mechanical problems in the conveyor