Lincoln Impinger X2 Ovens with Push Button Controls 3240-2 User Manual

Page 8

Advertising
background image

Impinger X2 – Analog Service Manual – Dom & Int’l

8

wiring back to the centrifugal switch of the burner

blower motor. If voltage is present, check for 24VAC at

pins #3 and #2 (pilot valve). If voltage is not present,

replace burner control. If the pilot valve is energized,

check to see that the high voltage igniter circuit is also

energized. To check, turn power off, disconnect the

igniter lead from the ignition control. Turn power on. If

no spark is visible, replace burner control. If a spark is

visible at burner control, proceed.

Pilot valve

Check for 24VAC supplied to pilot valve. If no voltage is

present, trace wiring back to burner control. If voltage is

present, check for gas pressure at the pilot line

connection. If no gas pressure is present during

ignition, check for any blockage in the assembly. If

there are no obstructions, and there is gas supplied to

the oven, replace the gas valve.

No pilot flame

If the ignition control is supplied with 24VAC and the

pilot valve and igniter circuits are energized, visually

check for a pilot flame. This may be done by looking

through the inspection view port on the end of the

burner. If no pilot flame is visible, check the pilot tube.

Pilot tube

Check for gas pressure at the pilot tube. Disconnect

pilot tube at the burner And connect manometer to pilot

tube. If no gas pressure is present during ignition,

check for blockage of the pilot tube. If the pilot tube is

clear, proceed.

Pilot orifice

If there is gas pressure at the pilot tube, check the pilot

orifice for blockage or obstructions. Replace pilot orifice

as needed.

Burner igniter

Check the burner igniter head for any damage or

obstructions also check for frayed or broken wire.

Check spark gap, gap should be 3/32” If there is visible

damage, replace burner igniter.

NOTE: Flame should be

On at this time

Pilot flame, but no main flame

Electronic temperature

control

Check for 120VAC supplied to electronic temperature

control at terminals #13 and #12. Of there is no voltage,

trace wiring back to the burner switch. Also check for

120VAC supplied to terminal #20 on the electronic

temperature control. If there is no voltage at terminal

#20, trace wiring back to terminal #13. Set temperature

control to maximum temperature and check for

120VAC output at terminal #21 and neutral. If 120VAC

is present at terminal #20 and neutral, and the unit is

not heating, refer to “Temperature regulation valve” for

next check. If 120 VAC is not present, proceed.

Thermocouple probe

WITH POWER ON AND THERMOCOUPLE LEADS

ATTACHED TO THE ELECTRONIC TEMPERATURE

CONTROL: Measure the D.C. millivolt output of these

leads. Refer to chart in the “Removal, Installation and

Adjustment” section for proper readings. If these

readings are not achieved, replace thermocouple.

Burner control.

Check for 24VAC supplied to main valve. If no voltage

is present, trace wiring back to burner control. If there is

no voltage output, replace burner control.

Main gas valve

Check to see that the switch on the valve is in the “ON”

position. Check for 24VAC supplied to main valve. If

there is voltage present, check to see that valve is

opening. Connect manometer to pressure tap on outlet

side of valve. If there is voltage to the valve, but no

output gas pressure, replace the valve.