HALL EFFECT SENSOR – REPLACEMENT

1.

Shut off power at main breaker.

2.

Remove control box cover.

3.

Disconnect all wiring from hall effect sensor and mark all wiring for reassembly.

4.

Remove mounting nut and remove hall effect sensor and magnet.

5.

Reassemble in reverse order and check system operation.

CONVEYOR CONTROL – REPLACEMENT

1.

Shut off power at main breaker.

2.

Remove control box cover.

3.

Remove top and rear covers from conveyor control. Disconnect all wiring from the conveyor control and

mark all wiring for reassembly.

4.

Remove two screws and remove faceplate from conveyor control. Remove two mounting screws and

remove conveyor control.

5.

Reassemble in reverse order, set control for proper programming (see CONVEYOR CONTROL -

PROGRAMMING) and check system operation.