Impinger X2 – Analog Service Manual – Dom & Int’l

14

On at this time

Electronic temperature

control

control at terminals #13 and #12. Of there is no voltage,

trace wiring back to the burner switch. Also check for

supply voltage to terminal #20 on the electronic

temperature control. If there is no voltage at terminal

#20, trace wiring back to terminal #13. Set temperature

control to maximum temperature and check for output

voltage at terminal #21 and neutral. If voltage is present

at terminal #20 and neutral, and the unit is not heating,

refer to “Temperature regulation valve” for next check.

If voltage is not present, proceed.

Thermocouple probe

WITH POWER ON AND THERMOCOUPLE LEADS

ATTACHED TO THE ELECTRONIC TEMPERATURE

CONTROL: Measure the D.C. millivolt output of these

leads. Refer to chart in the “Removal, Installation and

Adjustment” section for proper readings. If these

readings are not achieved, replace thermocouple.

Burner control.

Check for supply voltage to main valve. If no voltage is

present, trace wiring back to burner control. If there is

no voltage output, replace burner control.

Main gas valve

Check for supply voltage to main valve. If there is

voltage present, check to see that valve is opening.

Connect manometer to pressure tap on outlet side of

valve. If there is voltage to the valve, but no output gas

pressure, replace the valve.

Temperature regulation valve If supply voltage is present on the electronic

temperature control, terminal #13 to neutral, check for

voltage at temperature regulation valve. If no voltage is

present, trace wiring back to electronic temperature

control, terminal #20. If voltage is present, listen for

valve to open and close. Also check for opens or shorts

in the operating coil. Replace temperature regulation

valve as needed.

Intermittent heating

Thermal/Overload of main fan

and burner blower motors

The main fan motor and burner blower motor are

equipped with internal thermal protection and will cease

to operate if overheating occurs. As the motors over-

heat and then cool, this will cause the units to cycle on

and off intermittently. Improper ventilation or lack of

preventive maintenance may cause this. Also, most of

the problems listed under “Oven will not heat” can

cause intermittent failure.

Conveyor will not run

NOTE: The ovens may contain two, three or four conveyor drive systems using like

components. The trouble shooting sequence will be the same for each of the conveyor

drive systems

Power supply

Check circuit breakers, reset if required. Check power

plug to be sure it is firmly in receptacle. Measure

incoming power, call power co. if needed.

Switch, oven fan

Check continuity between switch terminals. Replace

switch as needed.

Relay, main fan

Check for supply voltage to relay terminal #13. If

voltage is not present, trace wiring back to power

supply. If voltage is present, check for supply voltage at

terminal #14. If there is no voltage at terminal #14, and

the relay is energized, replace the main fan relay.

Fuse, 2 Amp

Check, replace if necessary.

Fuse holder

Check for supply voltage to fuse holder. If no voltage is

present, trace wiring back to main fan relay. Check fuse

holder, replace if necessary.

Switch, conveyor

Check for supply voltage to conveyor switch. If no

voltage is present, trace wiring back to fuse holder.

Check continuity between switch terminals. Replace

Advertising