3-12

Service Manual

5021-0XX

3 = operational serial port #3.

P represents the number of times the test has passed
(finished successfully). Initially 000000 is displayed for
######. The maximum pass count is 999,999.

F represents the number of times the test has failed or
finished with errors. Initially 00000 is displayed for #####.
The maximum fail count is 99,999.

Note: The power indicator blinks indicating the test is running.

Each time the test finishes, the screen updates with the result. If
the test passes, the pass count increases by 1, however if the
test fails, one of the following failure messages displays for
approximately 3 seconds and the fail count increases by 1:

Once the maximum count is reached the test stops and the final
results display.

3. Press Return or Stop to exit the test.

Receive Status Interrupt Error

Status Error

Receive Data Interrupt Error

Transmit Data Interrupt Error

Transmit Empty Error

Threshold Error

Receive Data Ready Error

Break Interrupt Error

Framing Error

Parity Error

Overrun Error

Data Error

Data 232 Error

Data 422 Error

FIFO Error

DSR Error

DSR PIO Error

DSR Interrupt Error

CTS Error

CTS Interrupt Error

CTS PIO Error