Parallel strobe adjustment – Lexmark 5021-0XX User Manual

Page 226

Advertising
background image

3-18

Service Manual

5021-0XX

If the ID is valid then the ID is saved in NVRAM and the
printer automatically PORs to activate the new setting.

Note: When the printer PORs it does so in the normal mode.

Parallel strobe adjustment

This setting lets the user adjust the factory setting for the amount of
time strobe is sampled. This determines whether valid data is
available on the parallel port.

Increasing this value means that strobe is sampled 50ns longer.
Decreasing this value means that strobe is sampled 50ns shorter.

The range of this setting is -4 to +6.

Example of setting:

A value of 0 indicates no adjustment is sampled from the factory
setting.

A value of -1 indicates the sample strobe time is reduced by
50ns.

A value of +3 indicates the sampled strobe time is increased by
150ns.

Advertising