Lexmark 5021-0XX User Manual

Page 54

Advertising
background image

1-28

Service Manual

5021-0XX

5. Variation of the OPC belt potential:

a. The OPC belt is biased to -CBV(V).

b. The OPC belt surface is evenly charged to -Vo(V) during the

charging process.

c. During the exposing process, the optical unit emits a laser

beam that strikes the OPC belt surface forming an
electrostatic image. The electrostatic image is at -VR(V)
potential.

d. The negatively charged toner is moved to the OPC belt in

the development process due to the difference between
-VR(V) and -DBV(V). A visible image is the result.

e. The negatively charged toner on the OPC belt is moved to

the transfer belt because the potential GND of the transfer
belt is greater than -VR(V) of the OPC belt.

f. The OPC belt is discharged by the erase lamp radiating on

the OPC belt.

-CBV

-V0

Latent image

Toner image

TEST

PRINT

-CBV

-V0

-CBV

-V0

-CBV

-V0

-V0 -V0

-V0 -V0

-V0 -V0

-V0 -V0

-V0

-V0

TEST

PRINT

-V0

-V0

-CBV

-CBV

-CBV

-CBV

-V0

-V0

-V0

-V0 -V0

-V0 -V0

-V0 -V0

-V0 -V0

TEST

PRINT

Transfer belt

Blade

6

5

4

Erase lamp

OPC belt

1

2

3

Charging

Laser diode

exposing

Developing

K Y M C

0V

OPC belt surface

-VR

-CBV

-V0Charge brush

Discharge roller

OPC charging system

DCV

-CBV

-CHV

(-BRV)

Developer roller

-DBV

(M)toner

-DBV