NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Pilot Flame Appearance

Figure 31

Air Shutter Adjustment

CAUTION: Air shutter is hot while the Epic™ gas stove

is operating and should only be adjusted using a heat

resistant glove.

The air shutter control lever is located inside the main

control door above the control panel. The lever is linked to

the primary air shutter on the main burner. The air shutter

regulates the amount of primary air the burner receives

and, therefore, how clean the stove burns. The air shut-

ter should only be adjusted by a qualified gas technician.

The stove should burn for about 15 minutes with the logs

installed before adjusting the air shutter. Moving the lever

to the left (closing the shutter) will raise the height of the

flames as well as turn them more yellow/orange. Moving

the lever to the right will open the shutter, turning the flames

to a cleaner transparent blue and enhance the glow of the

logs. CAUTION: The air shutter should never be set so as

to make the tips of the flames sooty or create sooting on

the viewing glass, logs, or firebox ceiling. If soot begins

to form after burning, the air shutter should be opened

gradually until the sooting condition stops. Gas quality

and gas pressure may vary, which can affect the burning

characteristics of the stove.

Quiet Operation

As the Epic gas stove is burning, a number of normal op-

erational sounds may be heard. The flow of gas through the

gas valve and orifice may make a rushing or whistling noise.

If this noise is objectionable, it can be reduced by turning

down the flame. Turning down the flame can reduce total

heat output by more than 30%. When the blower turns on,

the sound of rushing air may be heard. The blower sounds

may be reduced by adjusting the speed control located on the

blower assembly. Also, a slight clicking sound may be heard

as the gas valve or blower switch is turned on and off.

Paint Curing

This stove has been painted with Stove Bright high tempera-

ture metallic paint. It leaves the factory dry to the touch, but

completes the curing process as the stove is used. To cure

the paint, burn the appliance four successive times for ten

minutes each time with a five minute cool down between

each firing. Also some parts of the appliance may be lightly

coated with machining oil. Ventilate the house during these

first firings as the paint and oil give off carbon dioxide and

unpleasant odors. It is recommended that persons sensi-

tive to an imbalance in the indoor air quality avoid the stove

during the curing process.

Optional Wall Thermostat

If an optional wall thermostat is to be installed, install the

thermostat per the manufacturers instructions (provided with

the thermostat). Failure to follow manufacturers instructions

could result in a malfunction. Pay special attention to the

thermostat location requirements. If the location require-

ments are not adhered to the appliance, erratic operation

or failure may occur.

Do not mount the thermostat where it may be affected by:

• Radiant heat from this appliance, fireplaces, sun or other

heat sources.

• Drafts or dead spots behind doors or in corners.

• Hot or cold air from ducts.

Air Shutter Adjustment Handle, highlighted

Closed Open

Loosen screws to adjust, tighten

screws when adjustment is complete.

Figure 32

Advertising
This manual is related to the following products: