NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Vent Pipe Maintenance

Conduct an inspection of the venting system semiannually.

Recommended areas to inspect are as follows:

1. Check areas of the venting system which are exposed to

the elements for corrosion. These will appear as rust spots,

streaks, or, in extreme cases, holes. These components

should immediately be replaced.

2. Remove the cap and shine a flashlight down the vent.

Remove any bird nests or other foreign material.

3. Check for evidence of excessive condensate, such as

water droplets forming in the inner liner and subsequently

dripping out at joints. Continuous condensate can cause

corrosion of caps, pipe and fittings. It may be caused by

having excessive lateral runs, too many elbows, or exterior

portions of the system being exposed to cold weather.

4. Inspect joints to verify that no pipe sections or fittings have

been disturbed and consequently loosened. Also check

mechanical supports such as wall straps or plumbers’

tape for rigidity.

Glass Door Cleaning and Maintenance

Cleaning: When cool, the glass may be cleaned with a clean,

soft cloth and glass cleaner. For cleaning white condensation

from the interior glass use KEL KEM gas stove glass cleaner

available from your stove dealer. Use of caustic or abrasive

cleaners may damage glass. Gold or nickel plated trim must

be cleaned with glass cleaner or denatured alcohol and a

soft cloth before firing or fingerprints and stains will remain

permanently. Never use abrasive polish to clean the gold or

nickel as it will ruin the finish. DO NOT operate stove with

broken glass. DO NOT clean door or glass when hot. DO

NOT abuse glass door by striking or slamming shut. DO NOT

use substitute materials if replacing glass. DO NOT spray

commercial glass cleaner with ammonia on the door and

glass gasket as it may dissolve the gasket glue.

WARNING: Do not operate appliance with the glass panel

removed, cracked, or broken. Do not remove glass door

while the stove is hot. Replacement of the glass door

should be done by a qualified service technician.

Glass Replacement: If the glass in your door is damaged

or broken, the complete door assembly (including gaskets)

must be replaced using part number H3102. The replace-

ment door assembly is available from your Lennox Hearth

Products dealer. The glass is neo-ceramic and alternative

types must not be used. See Page 25 for door assembly

replacement instructions.

WARNING: Do not operate appliance with the glass panel

removed, cracked, or broken. Do not remove glass door

while the stove is hot. Replacement of the glass door

should be done by a qualified service technician.