Clearances to Combustibles

Minimum clearances to combustible materials in inches

(millimeters):

Parallel Installation

Corner Installation

Alcove dimensions

The minimum width between the alcove side walls is 48”

(1219mm). The minimum height of the alcove is 69” (753mm)

and the maximum depth is 48” (1219mm).

Floor Protection

A noncombustible hearth pad is not required. This stove

may be installed on a combustible surface. Also, the floor

beneath the stove must be stable, level, hard and strong

enough to support the stove without a tipping hazard.

48”

(9mm)

Min.

48”

(9mm)

Max.

69”

(753mm)

Min.

Alcove Dimensions

4-/”

(6mm)

Min.

-/”

(38mm)

Min.

4” (0mm)

4-/”

(4mm)

Min.

4-/”

(4mm)

Min.

0-/”

(67mm)

Min.

90°

Figure 3

Figure 4

Figure 5

Pipe Clearances

All installations using a vertical termination cap must

maintain one inch clearance between the direct vent pipe

and combustibles. For horizontal runs of pipe, one inch of

clearance to combustibles on the sides and bottom and two

inches on the top of the pipe is required. See Page 16 for

allowable pipe configurations.